The Effect of Large Capsulorhexis (>7mm) on the Stability of Refraction Post Cataract Surgery

Chen, Ming (2012) The Effect of Large Capsulorhexis (>7mm) on the Stability of Refraction Post Cataract Surgery. British Journal of Medicine and Medical Research, 2 (1). pp. 86-93. ISSN 22310614

[thumbnail of MingChen_2011BJMMR771.pdf] Text
MingChen_2011BJMMR771.pdf - Published Version

Download (563kB)

Abstract

Purpose: To investigate if the larger capsulorhexis (7mm) is associated with a stable post-operative refraction with Acrysof IQ one-piece IOL (SN60WF, Alcon USA) implantation from 1month to 2 years after cataract surgery.
Method: Retrospective chart review was made on 31 eyes of 20 patients. All eyes had uncomplicated phacoemulsification by the author with 7mm capsulorhexis and Acrysof one-piece IOLIQ (SN60WF, Alcon USA) implantation between 4/2007 and 7/2008. IOL Master was used to select the IOL and target refraction was recorded. Refraction data by manifestation in spherical equivalent (SE) at one month, 3 month and 2 years were recorded and input to SPSS19.
Result: The mean refractions in spherical equivalent (SE) were statistically significant and excellent positively correlated among the preoperative target refraction (IOL master), one month post-op, three months post-op and two years post-op. P<0.01, Pearson correlation coefficient: r>+0.9 (95%CI 0.91 to 0.98)
Conclusion: The 7mm capsulorhexis with Acrysof one-piece IOLIQ (SN60WF, Alcon USA) implanted eyes demonstrated refractive stability from 1 month up to 2 years post operation.

Item Type: Article
Subjects: Archive Paper Guardians > Medical Science
Depositing User: Unnamed user with email support@archive.paperguardians.com
Date Deposited: 23 Jun 2023 07:26
Last Modified: 10 Jan 2024 04:14
URI: http://archives.articleproms.com/id/eprint/1329

Actions (login required)

View Item
View Item